Experimental study on simultaneous desulfurization and denitrification with ammonia in WFGD system combined with plasma oxidation of NO

Jubing Zhang,Ying Zhou,Zhaoping Zhong,Xiaoxiang Jiang,Guilin Piao
DOI: https://doi.org/10.3969/j.issn.1001-0505.2014.06.018
2014-01-01
Abstract:To increase the NO x removal efficiency in simultaneous desulfurization and denitrification of flue gas,the plasma oxidation technology was applied to the wet flue gas desulfurization (WF-GD)process.The testing apparatus for simultaneous desulfurization and denitrification with ammo-nia in WFGD system combined with plasma oxidation of NO was established.The effects of liquid-gas ratio,ammonia concentration,flue gas flow rate,flue gas temperature,NO initial concentration and SO2 initial concentration on the removal efficiency of SO2 and NOx were investigated.The re-sults show that higher liquid-gas ratio,higher ammonia concentration,lower gas flow rate,lower flue gas temperature,lower NO initial concentration and lower SO2 initial concentration contribute to higher NOx removal efficiency,while the SO2 removal efficiency remains almost the same under cor-responding experimental parameters.The removal efficiency of SO2 and NOx reach 99.6% and 69.4%,respectively,under the following conditions:liquid-gas ratio of 10 L/m3;ammonia con-centration of 4 mol/L;flue gas flow rate of 10 m3/h;flue gas temperature of 85 ℃;NO initial con-centration of 3.5 ×10 -4;SO2 initial concentration of 1.0 ×10 -3.
What problem does this paper attempt to address?