Measurement error for non-contact photo-electrical online shaftpower monitoring based on angle phase difference

Kun Yang,Qiu Qin,Mao Zou,Xinping Yan
DOI: https://doi.org/10.13245/j.hust.170517
2017-01-01
Abstract:Due to the correctness of the shafting torsional angle measurement determines the accuracy of the torque and power measurement result, the causes of measurement error were analyzed through researching the quantitative accuracy of the instrument, eccentricity and verticality of light code disc during the installation of shaft rotational, temperature drift of sensors and other aspects of the non-contact photoelectric shaft power meter.Mathematical relationship was analyzed between these reasons and final measurement error from the perspective of geometric and relative error, and various causes of error and error tolerance was deduced.The analysis results show that accuracy of measurement can be improved by the targeted installation adjustment, which has a great in fluence on the measuring error during the process of monitoring the equipment.The conclusions provide theoretical guidance to design and installation of the non-contact photoelectric shaft power meter and improve the measuring accuracy of this kind of equipment.
What problem does this paper attempt to address?