Study of fast ion loss detector system for HL-2A

Yi-Qin LIU,Yan HUA,Zuo-Bin ZHU,Wei CHEN,Xiao-Bing LUO,Yi-Po ZHANG,Yi LIU,Isobe Mitsutaka
DOI: https://doi.org/10.3969/j.issn.0490-6756.2013.06.025
2013-01-01
Abstract:Scintillator-based fast ion loss detector (SFLID) is widely used as an important tool of energet-ic ions diagnosis on fusion device .SFILD can simultaneously measure the energy and pitch angle of esca-ping fast ions with the striking point on the scintillator plane .According to the measuring requirements of HL-2A tokamak device ,a movable SFILD has been designed and installed in HL-2A .The movable SFLID has been used to detect lost fast ions in plasma discharge with neutral beam injection (NBI)on HL-2A .Images of fast ion loss have been obtained by this movable SFILD .In addition ,the improve-ments of the design of detector head are also discussed .
What problem does this paper attempt to address?