The effect of fast electrons on fast ion loss detector

Zhao JIN,Jiafeng CHANG,Juan HUANG,Chengrui WU,Shiyao LIN
DOI: https://doi.org/10.11889/j.0253-3219.2017.hjs.40.110605
2017-01-01
Nuclear Techniques
Abstract:Background: A scintillator-based fast ion loss detector (FILD) can simultaneously measure the energy and pitch angle of escaped fast ions, which is a powerful method to study the behavior of fast ion feature.Purpose: Investigating the performance of the fast ion loss is very helpful for understanding plasma confinement due to the development of experimental advanced superconducting tokamak (EAST).Methods: FILD has been successfully put into operation on EAST, and the behavior of fast ion can be analyzed by charge coupled device (CCD) and photomultiplier tube (PMT) data acquisition system.Results: When the neutral beams were injected, the fast ion losses were detected. Runaway electrons and the fast electrons were observed when lower hybrid waves were injected into plasma, resulting in the effect of X-rays on the fast ion loss signal. In H-mode discharge condition, the fast ion losses signal changed with D-alpha signals.Conclusion:Fast ion loss detector system plays an important role in investigating loss ions behavior during neutral beam heating. Runaway electrons and fast electrons would affect the fast ion loss signal. At the same time, FILD will be upgraded with the probe structure and new scintillator material will be selected to minimize the impact of X-ray.
What problem does this paper attempt to address?