Relationship Between Laser Ablation Threshold of Graphite-Sio2 and Scattering Light Signal

Li Wen-Zhi,Wei Cheng-Hua,Gao Li-Hong,Ma Zhuang,Wang Fu-Chi,Wu Tao-Tao
DOI: https://doi.org/10.3788/co.20160906.0642
2016-01-01
Abstract:As inorganic additional compositions 7 graphite and SiO2 have been widely used in ablation coating in the flied of aerospace. Since graphite and SiO2 have high endothermic enthalpy of reaction under high temperature, graphite-SiO2 composite has potential applications in the field of high power laser ablation resistance. At present, there are rare reports about laser ablation behavior of graphite-SiO2, especially the reaction time and ablation threshold. In this paper, the near infrared (NIR) detector was used to detect the scattering light from the irradiated sample surface 7 and the scattering spectra were processed by differential and fitting method. Based on the scattering signal, the reaction time thresholds of graphite-SiO2 under different power density were studied combining shape structure analysis of samples after ablation. The result shows that when the sample is irradiated by laser 500 W/cm(2) for 10 s, there is no mutation abserred in the scattering fitting curve, which indicates that no obvious ablation happened. But when the laser power density increases to 1 000 - 1 500 W/cm(2), the apparent turning point in the scattering fitting curve can be observed. The reaction thresholds are 1. 5 s and 0. 8 s, respectively. By using the laser scattering light signal from the sample surface, the time threshold value of graphite-SiO2 composite can be effectively characterized.
What problem does this paper attempt to address?