Test and Analysis of Flow Structure in a Furcated Duct

Xiang XUE,Tong WANG
2017-01-01
Abstract:The furcated duct is a common engineering device of flow distribution or an aircraft bypass construction,in which the structure of split flow affects the passing flow rate of main flow path.The generation and expansion of reflux vortex may cause obstruction of split flow and make it loss the effect of flow distribution.In this paper,the flow structure in the split flow channel was identified through high-speed photography test at first,and an obvious reflux vortex structure was found at the inlet of scavenge flow passage.Then,the wall static pressure near it was dynamic tested and recorded.The results of both the dynamic pressure test and high-speed photography captured the frequency information caused by the vortex flow field.It was further found that wall pressure variation near reflux vortex has chaotic characteristics at different inlet Reynolds number (Rein =80249 to 179414).With inlet Reynolds number increasing,pressure pulsation amplitude increases,the randomness decreases,certainty and stability enhance,especially vortex generation position,to affect the flow-passing capacity of split flow channel.