Research on the Control of Hub-Corner Separation in a Compressor With Stator Hub Gap

Cong-Peng L(U),Bin JIANG,Yi QIU,Guo-Qiang WANG,Kai WANG,Qun ZHNEG
2016-01-01
Journal of Engineering Thermophysics
Abstract:To research the control of hub-corner separation in a compressor with stator hub gap,a 1.5-stage axial flow compressor was studied by 3-D numerical simulation method.First,the integral equal hub gap was studied,and then to the integral trapezoidal hub gap,after that to the partial hub gap,and finally the trailing edge hub gap was put forward.The results show that integral hub gap can improve the performance of compressor by eliminating the hub-corner separation at low-operating point,but it's also paid the price of decreasing the performance at design point,and the integral trapezoidal hub gap is significantly better than the integral equal hub gap.For the trailing edge hub gap,with the position of partial gap moving backward,the ability to control the hub-corner separate is gradually enhanced,and the damage to the performance of design point is gradually reduced.At last,the trailing edge hub gap was put forward,the massflow of the low-operating point is increased by 0.88kg/s,the efficiency is increased by 1.37% and the pressure ratio is increased by 0.15% without performance deterioration at the design point by choosing a certain size trailing edge hub gap.
What problem does this paper attempt to address?