Abstract:A Cryogenic Permanent Magnet Undulator (CPMU) for the insertion device system of high energy photon source test facility (HEPS-TF) was under the development.An in-vacuum girder is a key part which supports magnet and works at cryogenic and vacuum conditions.Deformation of an in-vacuum girder caused by cryogenic contractility will lead to magnetic er-ror directly.Magnetic field errors like phase error must be guaranteed to acquire high coherence synchrotron radiation photon.In this article,an in-vacuum girder deformation were calculated and discussed,its optimization and compensation were made to reduce and eliminate the deformations so as to obtain a high quality magnetic field.