Performance investigation of conduction-cooled cryogenic permanent magnet undulator at high beam currents

Jui-Che Huang,Hideo Kitamura,Chih-Shen Yang,Ching-Kang Yang,Chih-Wei Chen,and Yu-Chun Chuang
DOI: https://doi.org/10.1103/physrevaccelbeams.27.023501
2024-02-07
Physical Review Accelerators and Beams
Abstract:A conduction-cooled cryogenic permanent magnet undulator, CU15, with a period length of 15 mm and 133 periods has been successfully developed. This undulator has been operated at the Taiwan Photon Source (TPS) storage ring at a beam current of 500 mA for more than 3 years. In CU15, two cryocoolers are used to cool the PrFeB magnets to 80 K. The effective magnetic field measures 1.33 Tesla for a magnet gap of 4.2 mm, maintaining an rms phase error below 2.6°. The bunch length of the electron beam in TPS is as short as 16 psec, leading to a serious issue with high beam-induced heating in CU15. This report addresses the above issues and provides detailed adaptations of CU15 to operate at a beam current of 500 mA. https://doi.org/10.1103/PhysRevAccelBeams.27.023501 Published by the American Physical Society under the terms of the Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI. Published by the American Physical Society
physics, particles & fields, nuclear
What problem does this paper attempt to address?