The Adjustment Of Rf System For Hefei Storage Ring

Hl Xu,L Wang,Yb An,Sy Jiang,Bg Sun,Wm Li,Zp Liu,Dh He
DOI: https://doi.org/10.3321/j.issn:0254-3052.2003.05.018
2003-01-01
Abstract:The effects of the parameters of RF system to electron beam intensity in Hefei storage ring are discussed in this paper. There appeared significant deviation respect to bean ideal orbit in the closed orbit distortion correction experiment, and therefore, necessary adjustments have been carried out for RF system parameters, such as frequency, cavity temperature, etc. ' to meet the requirement of intense beam injection. And the work have guidance effect to reconstruction of RF system in Phase II project of Hefei storage ring.