Influence of Thermal Loading on Bearing Capacity of Geothermal Energy Piles

Pengfei FANG,Abdelmalek Bouazza,Wang Bill,Zhongjin WANG,Xinyu XIE
DOI: https://doi.org/10.13409/j.cnki.jdpme.2017.04.005
2017-01-01
Abstract:As a kind of GSHP (Ground Source Heat Pump),geothermal energy piles is the economic,stable,efficient,and environmentally friendly way of cooling and heating building.Based on four published field and centrifugal model test studies,the bearing capacity and mobilized stress of pile shaft and lateral friction resistance under the thermal loading are analyzed.At the same time,a model test in sand is done.Its results indicate that the lateral friction decreased with the increasing temperature,which is opposite to the former one.At last,the interaction mechanism between geothermal energy pile and soil is analyzed.When the geothermal energy piles are heated,the bearing capacity will be increased,and the friction resistance of the upper pile will be decreased.In contrast,the friction resistance of the low pile is increased.At the same time,the axial in pile will be enlarged.Whilst the geothermal energy piles are cooled,the friction resistance of the upper pile will be increased,and that of the low pile is decreased.There is even tensile stress in pile under the special case.
What problem does this paper attempt to address?