Flow control method for wake suppression of circular pipes based on parellel dual plates

Bing SUN,Jinxuan LI,Yan BAO
DOI: https://doi.org/10.16483/j.issn.1005-9865.2015.03.014
2015-01-01
Abstract:In this paper, we numerically investigated wake suppression of the flow behind circular pipes by using parallel splitter plates. A stabilized finite element method is used for the solution of the two-dimensional Navier-Stokes incompressible equations governing the separated flows over the pipe-like structures. The effects of fixing angle and plate length on the bluff body wake are discussed in detail. The numerical results show that the control efficiency of the current method could be significantly improved when compared with the traditional single splitter-based method. The wake instability can be completely suppressed for the relatively shorter plate length and the optimal position angle of the parallel plates is approximately between 40°~50° from the rear base point of the circular pipe. When the fixing angle is larger than 80°, the pressure distribution along the surface of controlled cylinder looks very similar to that of the uncontrolled case, showing the dual plate control no longer works for drag reduction effect. Finally, the flow mechanisms in relation to the wake control of the developed strategy are given based on the numerical analysis.
What problem does this paper attempt to address?