Application of key technology changing bag filter to electrostatic precipitator in ultra-low emission upgrading projects of coal-fired power plants

Xueming FAN,Lei WANG,Yuanyuan SANG,Shilong WANG,Ping HAN,Qinzhen ZHENG,Keping YAN
DOI: https://doi.org/10.3981/j.issn.1000-7857.2017.15.007
2017-01-01
Abstract:This paper presents a pioneer project of changing the bag-filter into colder-side electrostatic precipitator (ESP) for two 600 MW coal-fired boilers of Shanxi Luneng Hequ Power Plant for ultra-low emission of particle matters (PM) and sulfur dioxide (SO2) by cooperative optimization of colder-side ESP with three-phase power source and wet flue gas desulfurization (WFGD).Due to the coal-fired boiler condition and initial bag filter size,we change bag filter into ESP by taking ESP sizing,gas flow distribution optimizing,three-phase power source,etc.into consideration.The main result of this paper is when the ESP's specific collection area is 83.5 m2/(m3· s) with three-phase rectifier transformer and the inlet ash load concentration is around 35.8 g/m3,the outlet particle mass concentration is 9.93~14.69 mg/ m3,of which the mass concentration of particles with diameters of less than 2.5 μm is below 1.58 mg/m3.The integration of colder-side ESP with three-phase power source and WFGD can achieve ultra-low emissions of air pollutants for coal-fired power plants.
What problem does this paper attempt to address?