Operation performance of electrostatic precipitator in circulating fluidized bed boiler in wide load range

Qinzhen ZHENG,Jiafeng LI,Hui FU,Yifan HUANG,Zhen LIU,Keping YAN
DOI: https://doi.org/10.19666/j.rlfd.201704003
2018-01-01
Abstract:In order to enhance the adaptability of electrostatic precipitator (ESP) to wide load range condition of circulating fluidized bed (CFB) boiler, an experimental research about the ESP operating power and emission control was carried out in a 135 MW CFB boiler, and the relationship between the particulate matters emission concentration and ESP operating power was obtained. The results indicate that, due to the variation in unit load, the flue gas temperature changed, which directly affected operating power of the ESP, so dust removal effect of the ESP is very sensitive to the boiler load change. With the flue gas temperature ranging from 100℃ to 200℃, the operating power of the ESP would increase by about 100 kW and the dust specific resistance would reduce by about 1 magnitude when the flow gas temperature reduces by about 20℃. Decreasing the flue gas temperature plays an important role in keeping the ESP operating stably with a high efficiency.
What problem does this paper attempt to address?