Determination of p-Phenylene diamine in the air of workplace by high-performance liquid chromatography

Baofeng LIU,Jian ZHANG,Ming ZHANG,Jing LIU,Wanchao ZHANG,Yushuai ZHANG,Shulan ZHAO,Qiang ZENG
2017-01-01
Abstract:Objective To establish the detection method for p-Phenylene diamine (PPD) in the air of workplace by highperformance liquid chromatography.Methods The air sample of PPD was quantitatively detected by the method of external standard after a series of steps collection with shocking absorber tube containing 5.0mL methyl alcohol solution followed by direct sampling separated with a Eclipse XDB-C18 column and tested with a ultraviolet detector.Results The PPD standard curve showed a good linear relationship under the mass concentration of 0.5-5.0mg/L(correlation coefficient =0.999 03).The air samples were calculated according to 45.0L the minimum average desorption efficiency was 0.004mg/m3;the within-run precision of the average desorption efficiency was 0.66%-2.14% and the between-run precisions was 1.01%-4.17%;the average sampling efficiency was 99.4%;The samples could be stably kept at 4℃ for 4d at least.Conclusion This method could be used for detection PPD in the air with high sensitivity precision and simple operation.
What problem does this paper attempt to address?