Exploration for automatically delineation of organ at risk based on medical case number of template database in MIM software

谷珊珊,田娟秀,王运来,宋明永,王金媛,王晓深,鞠忠建
DOI: https://doi.org/10.3969/J.ISSN.1672-8270.2018.03.001
2018-01-01
Abstract:Objective: To investigate the effect of the number of medical case for the automatic delineation on organ at risk based on template database of MIM software, and to guide clinical practice to select optimal amount of cases so as to constitute database of automatic delineation. Methods: 150 patients with nasopharyngeal carcinoma were divided into four groups that included of group a (10 cases), group b (50 cases), group c (100 cases) and group d (150 cases). And the database of four groups was constructed in the MIM software. And the database included of CT image and the outline information of organ at risk that delineated by manual operation of doctor. At the same time, the CT images of head of other 10 patients who weren't in the database were automatically delineated for organ at risk. And the automatic delineations were compared with gold standard that delineated by manual operation of doctor. The dice similarity coefficient (DICE), Hausdorff distance and Jaccard distance were used to evaluate the organ at risk of automatic outline. Results: The DICE values of four group were between 0.5 and 0.9. And all of the DICE values of eyeball, inner ear, oral cavity, parotid gland and other organs were higher than 0.8. And all of the means of Hausdorff distance (standard deviation) of eyeball, inner ear, temporomandibular joint, crystal and other organ or tissue at risk were less than 0.2. The Jaccard distance was minishing with the increasing of amount of cases in the template database, and all of the means of inner ear, temporomandibular joint, crystal and optic nerve were less than 0.4. Conclusion:With the increasing of amount of cases in the template database, the DICE values of eyeball, inner ear, spinal marrow, optic nerve and other organs will be higher, while the Hausdorff distances (standard deviation) of eyeball, inner ear, optic nerve and other organs will be smaller, and the Jaccard distances of each organ at risk will also be smaller. The organs at risk included of eyeball, inner ear, spinal marrow, optic nerve and others should adopted template database with more amount of cases to achieve automatic delineation. Besides, the amount of cases in the template database has no effect for the automatic delineation of brainstem, temporomandibular joint, crystal, oral cavity, parotid gland and other organ or tissue at risk.
What problem does this paper attempt to address?