Design and Analysis on Shielding Reconstruction Project of Brachytherapy Room

HAO Long-ying,MA Yong-zhong
DOI: https://doi.org/10.13329/j.cnki.zyyjk.2015.0710
2015-01-01
Abstract:[Objective]To determine the reasonable shielding reconstruction project of brachytherapy room according to the radiation protection requirements of different brachytherapy equipments, provide guidance for radiation protection of brachutherapy.[Methods]A192Ir brachytherapy room to be reconstructed and a60 Co brachytherapy equipment to be installed in a hospital in Beijing in 2014 were selected as the research objects,and the shielding reconstruction project of room was estimated and confirmed according to the control goal of dose rate and the relative national and international technology criterions including GBZ/T 201.1-2007,GBZ/T 201.3-2014,GBZ 121-2002 and IAEA No.47. [Results]The radiation dose rate outside the 74GBq60 Co brachytherapy room to be reconstructed from a 370 GBq192 Ir brachytherapy room were calculated,and the shielding reconstruction project of brachytherapy room was drawn as follows:1concrete shielding with thickness of 30 cm,20 cm,15 cm and 30 cm should be added to north,east,south and ceiling wall of the room respectively;2concrete shielding with thickness of one HVL should be added to internal maze wall of the room or the protective door should be replaced with another one with the lead thickness of 6 mm. [Conclusion]Combining with the radiation parameters of60 Co brachytherapy radioactive source,local shielding reconstruction on the basis of original192 Ir brachytherapy room is reasonable and feasible.
What problem does this paper attempt to address?