Effects of refractory ceramic fibers on workers' small airway function

Yishuo Gu,Wenjun Ma,Xiaojun Zhu,Hongfei Wang,Pei Xiao,Juan Chen,Yacai Cen,Tao Li
DOI: https://doi.org/10.13631/j.cnki.zggyyx.2017.06.001
2017-01-01
Abstract:Objective To explore the effects of refractory ceramic fibers (RCFs) on workers' small airway function.Methods This study enrolled 77 manufacturing and processing workers as the exposure group and another 80 workers neither exposed to RCFs nor other occupational toxicants as the control group.Low and high exposure subgroups were divided by the number concentration of fiber≤0.5 f/ml,>0.5 f/ml and by the gravimetric concentration of total dust ≤5 mg/m3,>5 mg/m3.According to the actual exposure level of fiber,62 exposed workers were classified as low fiber exposure level,15 exposed workers were classified as high fiber exposure level.According to the actual exposure level of total dust,47 exposed workers were classified as low total dust exposure level,30 exposed workers were classified as high total dust exposure level.All subjects accepted pulmonary function test.Maximal mid expiratory flow (MMEF),forced expiratory flow after 50% of the FVC has been exhaled (V50),forced expiratory flow after 75% of the FVC has been exhaled (V25) were measured as small airway function indicators.Analyses of variance,chi-square tests,and unconditioned logistic regression analyses were used to analysis positive rates of small airway dysfunction and influence factors of RCFs workers with different exposure features and difference exposure years.Results Mean values of V50%,V25%,and MMEF% were increased along with the fiber exposure level,but there were no statistically significant difference (P>0.05).Abnormal rates of V25% and MMEF% showed a positive linear relationship with the fiber exposure level (Ptrend <0.05).Compared with the control group and low total dust exposure level group,high total dust exposure level group had significantly lower mean values of V50%,V25%,and MMEF% (P<0.05) and correspondingly had significant higher abnormal rates of V50%,V25%,and MMEF% (P<0.05).High total dust exposure level group (33.3%) also had significant higher positive rates of small airway dysfunction than the control group (10.0%) and low total dust exposure level group (8.5%) (P<0.05).The small airway dysfunction was associated with the gravimetric concentration of total dust (OR=2.115,P<0.05),but was not related to the number concentration of fiber,the exposure years and smoking habit (P> 0.05).Conclusion Exposure to RCFs can harm the pulmonary small airway function.The high concentration of total dust in workplace can significantly increase the incidence of small airway dysfunction of RCFs exposed workers.
What problem does this paper attempt to address?