Determination of Puerarin and Baicalin in Gegen Qinlian Micropill by HPLC

ZHANG Ke-wei,CAI Hao,CHI Yu-mei,CUI Xiao-bing,LI Wei
DOI: https://doi.org/10.3969/j.issn.1001-1528.2005.01.014
2005-01-01
Abstract:AIM: To establish a HPLC for determination of puerarin and baicalin in Gegen Qinlian Micropill. METHODS: A Kromasil C 18 Column was used. The mobile phase was methanol-0.2% phosphoric acid. Puerarin and baicalin were determined by dual wavelength, λ 1=250nm. λ 2=315nm. RESULTS: The linear range of puerarin was within 32.0 ng—288.0 ng,r=0.9998 and the sample recovery was 100.17 % (RSD=1.00%(n=9)). The linear range of baicalin was within 52.6 ng~447.1 ng, r=0.9999 and the sample recovery was 100.06 % (RSD=1.06% (n=9)). CONCLUSION: This method has good repeatability and flexibility. It can be used for quality control of Gegen Qinlian Micropill.
What problem does this paper attempt to address?