T he Content Determination and Optimization of T hree Virtual Components in Gegenqinlian Injection by HPLC
HE Min,SHU Gang,YANG Le,ZHANG Wei,FU Hua-lin
DOI: https://doi.org/10.3969/j.issn.1004-3268.2014.06.034
2014-01-01
Abstract:In order to establish a simple HPLC method for determining the content of three virtual components in Gegenqinlian injection ,Kromsil ODS column(250 mm × 4.6 mm ,5 μm) was used . The HPLC system for puerarin ,baicalin ,berberine used the mobile phase composed of methanol-water(30∶70 ,V/V ) ,methanol-water-phosphoric acid(40∶60∶0.2 ,V/V ) and acetonitrile-water-potassium dihydrogen phosphate (32∶68∶0.3 ,V/V ) ,respectively ,with a flow rate of 1.0 mL/min and the column temperature was maintained at 25 ℃ .The detection wavelength was set at 251 nm , 280 nm and 348 nm ,respectively .The results showed that the puerarin calibration curve was linear in the range of 0.7 -4.2 μg/mL with the average recoveries was 98.8% .The calibration curve of baicalin was linear in the range of 4.3 -25.8 μg/mL with the average recoveries was 95.3% .The calibration curve of berberine was linear in the range of 4.0-24.0 μg/mL with the average recoveries is 96.4% .The content of puerarin ,baicalin and berberine was controlled as qualified more than 2.086 mg/mL ,2.573 mg/mL and 6.836 mg/mL ,with CV for within-run assays was less than 2% and CV for between-run assays was 3% ,respectively .This method was accurate ,convenient and quick .It can be used for Gegenqinlian injection quality control .