Determination of Baicalin Content in Xinqin Tablet by HPLC

Chenwen Li,You Cheng,Daqiang Hu,Mingfeng Xiang,Jing Xu,Hongyu Song,Bing Liu,Laichun Lu
2015-01-01
Abstract:Objective To establish a high performance liquid chromatography ( HPLC ) method for the determination of the baicalin con-tent in Xinqin Tablet. Methods The Diamonsil C18 column(250 mm × 4. 6 nm,5 μm) was used. The mobile phase was methanol-0. 1% phosphoric acid-triethylamine(57 :43 :0. 1). The detection wavelength was 280 nm. Results The linear range of baicalin was 1. 971-19. 71 mg/L( r=0. 999 9). The average recovery rate was 103. 01% ,RSD=1. 84%( n=9). Conclusion The established method is simple,specific and better repeatable,which can effectively control the quality of Xinqin Tablet.
What problem does this paper attempt to address?