The Value of CO2 Angiography in Function Evaluation of Dialysis Accesses

戎殳,李惠民,叶朝阳,严昺,肖湘生,梅长林
DOI: https://doi.org/10.3969/j.issn.1009-587X.2005.09.007
2005-01-01
Abstract:Objective:To investigate the value of CO_2 angiography in function evaluation of dialysis access.Methods:Using a Toshiba DSA unit, CO_2 angiography was undertaken in 10 patients with chronic renal failure through native arteriaovenous fistulas for hemodialysis. The urine volume and remaining GFR were measured before and after the examination.Results:All patients had a safe examination.A significant draining vein was revealed in 3 cases with good clinical function.And the abnormalities were revealed in 7 cases with malfunction.All of the draining veins above the elbow were clearly visualized.Conclusion:CO_2 angiography is safe, cheap, and efficacy for dialysis access surveillance.