CT Angiography of Autogenous Arteriovenous Fistula for Hemodialysis: A Preliminary Report

Li Huimin,Yu Hong,Liu Shiyuan
DOI: https://doi.org/10.19627/j.cnki.cn31-1700/th.2005.06.013
2005-01-01
Abstract:Purpose:To evaluate CT angiography of the autogenous arteriovenous fistula(AAF)for hemodialysis with a16-slice scanner.Materials and Methods:Seven chronic renal failure patients with hemodialy-sis were enclosed with12standard fistulas and2elbow fistula.CT angiography was undertaken with1mm thickness,0.8mm reconstruction interval,low-pass filter,and the reconstruction technique of volume rendering(VR),maximum intensity projection(MIP),and multiple/curved planar reconstruction(MPR or CPR).A total of90ml of noniodinated iopamidol contrast material was administered at a rate of3ml/sec into an antecubital vein of contralateral limb.Imaging commenced after a delay of25~30seconds.Re-sults:The vessels in diseased limb(including4arcus arteriosus manus)were clearly displayed on CTA.All of supplying artery were normal.Of the drainning veins,6occluded and collateral pathway generated at forearm and elbow,and19stenoses were found including4in the anastomoses,6in near-anasto-moses,and8in other sites.1thrombosis was revealed in the stent of brachiocephalic vein.Conclusion:CTA could reveal the autogenous AVF and its relationship,which might help clinical interpretation and treatment.
What problem does this paper attempt to address?