Preliminary evaluation of an indirect hemagglutination assay kit on early diagnosis of schistosomiasis japonica

Chengsong Sun,Lesheng Zhang,Hai Zhu,Yue Wang,Fengfeng Wang,Li Zhou,Xiaomei Yin,Qizhi Wang,Shiqing Zhang,Tianping Wang
DOI: https://doi.org/10.3969/j.issn.1672-2302.2016.03.001
2016-01-01
Abstract:Objective To preliminarily evaluate an indirect hemagglutination(IHA) assay kit for early di?agnosis of schistosomiasis japonica. Methods Rabbit models were infected with Schistosoma japonicum. The sera were collected from infected and non-infected rabbits on week 1, 2, 3, 4, 5 and 6, respectively, after infection, and subjected to detection using IHA assay kit and enzyme-linked immunosorbent assay(ELISA) based on the antigen X (X-ELISA). Then the two methods were compared regarding the outcomes in early diagnosis of schistosomiasis japonica. Results IHA assay kit revealed 0% positive serum from non-infected rabbits and from infected rabbits in the 1st and 2nd week after infection and 100% positive results from the 3rd week after infec?tion. Contrarily, X-ELISA indicated false positive rate of 30.77%in the sera of non-infected rabbits, and 0%and 16.67% positive results in the 1st and 2nd week after infection, and 100% positive results by the 3rd week. The difference was not significant regarding the positive rate measures at the same time point by two tech?niques(P>0.05). Conclusion IHA assay kit has potential value in early diagnosis of schistosomiasis japonica.
What problem does this paper attempt to address?