Reproducibility of voxel-based measurement of bone mineral density and cortical thickness of the proximal femur

Yanyu LIN,Ling WANG,Rui ZHANG,Minghui YANG,Xinbao WU,Xiaoguang CHENG,Xin GAO
DOI: https://doi.org/10.3969/j.issn.1006-7108.2018.06.003
2018-01-01
Abstract:Objective To provide a technical support for the study of hip fracture, quantitative computed tomography (QCT) was used to analyze the repeatability of voxel-based measurement of proximal femur bone mineral density (BMD) and cortical thickness (CTh).Methods 28 hip fracture patients who had two CT scans in a short time were selected, including 6 males and 22 females.Proximal femur was segmented from QCT image manually.With the idea of voxel-based morphometry (VBM), one proximal femoral structure of the average shape and structure was selected as the standard template, and other proximal femurs were mapped to the standard template by the elastic registration algorithm.CT values were converted to BMD and CTh using the Least Squares and the Levenberg-Marquardt method .Finally, using Statistical Parametric Mapping (SPM) method , we analyzed the BMD and CTh of proximal femur in 28 fracture patients who had two QCT scans in a short time, and obtained three-dimensional statistical parameter map.Results There were no significant differences in the measurement result of proximal femur BMD and CTh of the 28 fracture patients with two QCT scans in a short time (P >0.05), and the result of these two scans had good consistency.This indicates that the measurement result are accurate.Conclusion The voxel-based measurement of proximal femur BMD and CTh has good repeatability and provides an effective method for the risk assessment of hip fracture.