A Novel Calcium Phosphate–Based Nanocomposite for Augmentation of Cortical Bone Trajectory Screw Fixation
Yuetian Wang,Chun Liu,Huiling Liu,Haoyong Fu,Chunde Li,Lei Yang,Haolin Sun
DOI: https://doi.org/10.2147/IJN.S365149
IF: 7.033
2022-07-09
International Journal of Nanomedicine
Abstract:Yuetian Wang, 1, &ast Chun Liu, 2, &ast Huiling Liu, 3 Haoyong Fu, 1 Chunde Li, 1 Lei Yang, 3, 4 Haolin Sun 1 1 Department of Orthopedics, Peking University First Hospital, Beijing, People's Republic of China; 2 Medical Research Centre, Changzhou Second People's Hospital Affiliated to Nanjing Medical University, Jiangsu, People's Republic of China; 3 Institute of Orthopedics, Department of Orthopedics, Soochow University, Suzhou, People's Republic of China; 4 Center for Health Sciences and Engineering (CHSE), School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, People's Republic of China &astThese authors contributed equally to this work Correspondence: Lei Yang; Haolin Sun, Tel +86 13681146156, Email ; Purpose: To evaluate the effect of cement augmentation of cortical bone trajectory (CBT) screws using a novel calcium phosphate–based nanocomposite (CPN). Material and Methods: CBT screws were placed into cadaveric lumbar vertebrae. Depending on the material used for augmentation, they were divided into the following three groups: CPN, polymethylmethacrylate (PMMA), and control. Radiological imaging was used to evaluate the cement dispersion. Biomechanical tests were conducted to measure the stability of CBT screws. A rat cranial defect model was used to evaluate biodegradation and osseointegration of the CPN. Results: After cement augmentation, the CPN tended to disperse into the distal part of the screws, whereas PMMA remained limited to the proximal part of the screws (P 0.05). The axial pullout test showed that the average maximal pullout force (Fmax) of CPN-augmented CBT screws was similar to that of the PMMA group (CPN, 1639.56 ± 358.21 N vs PMMA, 1778.45 ± 399.83 N; P = 0.745) and was significantly greater than that of the control group (1019.01 ± 371.98 N; P 0.05). The CPN could be biodegraded and gradually replaced by newly formed bone tissue after 12 weeks in a rat cranial defect model. Conclusion: The biocompatible CPN could be a valuable augmentation material to enhance CBT screw stability. Keywords: cement augmentation, CBT screws, osteoporotic spine, PMMA, CPN Posterior pedicle screw fixation systems have widely been used in the treatment of spinal diseases. However, pedicle screw loosening, especially in the spine with lower bone quality, is still a common problem faced by surgeons. It has been reported that the rate of screw loosening in osteoporotic patients could be ≤60%, 1 which increases the risk of instrument failure. The cortical bone trajectory (CBT) screw technique is an existing method used to enhance screw anchorage and it works by increasing the contact area between the screw and the more rigid cortical bone. 2 Due to the cranial screw insertion occurring through a caudomedial starting point, the CBT screw technique achieves less-invasive fixation than traditional pedicle screws by limiting dissection of the superior facet joints and reducing muscle dissection and retraction, which has led to its increasing popularity among spinal surgeons. 3,4 However, some studies have concluded that the stability of CBT screws cannot surpass that of traditional pedicle screws. 5,6 Shorter and smaller screws inserted in vertebrae may incur higher stress, and micro-motions of the screws and bone encroachment around the screws accelerate once screw loosening occurs. 7 It has also been reported that the loosening rate of CBT screws in clinical practice is up to 6.5%. 8 Thus, there is a need to further enhance CBT screw stability, especially given the increasing number of aging patients. The cement augmentation technique may be a useful method to increase pedicle screw stability. However, early screw loosening remains a concern when treating patients with severe bone loss. While increasing the injected cement volume would strengthen the holding power, it simultaneously would raise the rate of complications related to cement, such as cement leakage or even pulmonary cement embolism. 9,10 Currently, the most widely used augmentation material is polymethylmethacrylate (PMMA), which has some advantages, -Abstract Truncated-