Hybrid Iterative Reconstruction Techniques iDose4 and Iterative Model Reconstruction in Low Dose Scanning Protocol for Response Assessment of Post-Operative Gastrointestinal Tumor Evaluation: Clinical Research

王梦如,辛小燕,杨尚文,胡安宁,刘松,朱斌
2017-01-01
Abstract:Objective To evaluate the application of the hybrid iterative reconstruction techniques algorithm (iDose4)and iterative model reconstruction(IMR) technique at low dose CT scan,and to compare the image quality of IMR with iDose4 for response assessment of post-operative gastrointestinal tumor evaluation.Methods 30 cases with post-operative gastrointestinal tumors were retrospectively analyzed.These 30 cases underwent dynamic enhanced CT scan at routine dose and followed up with dynamic enhanced CT scan at low dose 6 months later.Portal vein phases of routine and low dose scanning data were taken as the research object.Routine dose CT images were reconstructed with filtered back projection (FBP),and low dose CT images were reconstructed with iDose4 and IMR.3 data sets were obtained:GroupA (routine doseFBP),Group B1 (low dose-iDose4) and GroupB2 (low dose-IMR).Images were evaluated for objective analysis of hepatic CT value,noise,signal-to-noise ratio(SNR),contrast-to-noise ratio(CNR) as well as subjective analysis of image quality scores,and to statistically compare the radiation dose.Results Compared with routine dose scanning,low dose scanning reduced radiation dose by 51.47% and the differences were statistically significant(P <0.05).Image subjective scores:without significant statistical differences(P > 0.01) and these three groups of images all met the diagnostic requirement.In the objective evaluation,the hepatic CT value of these three groups of images were similar without significant statistical differences(P > 0.05).Increased image noise and decreased SNR were documented in Group B1 compared with Group A(P >0.01),while decreased image noise and increased SNR were documented in Group B2 compared with Group A (P <0.01).Compared with Group A,the CNR of Group B1 and Group B2 both increased(P < 0.01),and Group B2 increased more significantly than Group B1 (P < 0.01).Conclusion Significant radiation dose reduction and steadily maintained image quality can be achieved by using low dose scanning combined with iDose4 and IMR.Compared with iDose4,IMR significantly reduces the image noise and enhances image quality for response assessment of gastrointestinal tumor evaluation.
What problem does this paper attempt to address?