Experimental study on polyp detectability of ultralow-dose 640-slice CT colonography with adaptive iterative dose reduction three-dimensional reconstruction

ShenHesong,LiangDan,LuoMingyue,DuanChaijie,Wenli Cai,QiuJianping,LiWenru,ZhuDongyun
DOI: https://doi.org/10.3969/j.issn.1671-8348.2016.03.031
2016-01-01
Abstract:Objective To experimentally investigate polyp detectability of ultralow‐dose 640‐slice CT colonography with a‐daptive iterative dose reduction three‐dimensional (AIDR3D) reconstruction .Methods Ten segments of porcine colonic phantom were established .There were thirty pedunculated polyps with diameters ranging between 1 mm and 15 mm on colon mucosal sur‐faces of each segment .All phantoms were scanned using a 640‐slice CT scanner with tube voltage of 120 kVp ,and current doses of 10 ,20 ,30 ,40 ,50 mAs ,respectively .CT colonography images were obtained after reconstructing scanning image data with filtered back projection (FBP) and AIDR3D algorithms .Two radiologists without knowing scanning current doses and reconstruction algo‐rithms independently analyzed images .Confidence of polyp detection was divided into five grades for each radiologist ,and its agree‐ment was evaluated using Kappa analysis .Radiation dose was calculated based on dose‐length product that was exported on CT scanner .Polyp detection sensitivities with five scanning current doses and two reconstruction algorithms were statistically analyzed . Results Agreement in confidence of 3 000 polyps detection by two radiologists was good (κ=0 .740) .Compared with 50mAs with FBP ,20 mAs with AIDR3D had the same detection sensitivity of 100% for simulated polyps of 1- <6 ,6- <11 and 11-15 mm . Effective radiation dose of 20 mAs with AIDR3D (1 .62 mSv) was decreased by 60 .00% compared with 50 mAs with FBP (4 .04 mSv) ,their difference was statistically significant(P<0 .05) .As for 10 mAs with AIDR3D ,detection sensitivity for simulated polyp of 1- < 6 mm(77% ) was lower than that using 50 mAs with FBP (100% ) ,their difference had statistically significance(P<0 .05);detection sensitivity for simulated polyp of 6- <11 mm (98% ) was also lower than that using 50 mAs with FBP(100% ) . Conclusion Polyp detectability of ultralow‐dose of 20 mAs 640‐slice CT colonography with AIDR3D could comparable to that of standard low‐dose of 50 mAs with FBP ,with detection sensitivity of 100% ,its effective radiation dose reduced by 60 .0% and was only 1 .62 mSv .
What problem does this paper attempt to address?