GC Determination of 8 Kinds of Residual Solvents in Simvastatin

WEI Min-ji,LI Dong-mei
2007-01-01
Abstract:Objective:To establish a method for determination of the residues of 8 kinds of solvents by capillary gas chromatography.Method:The capillary column was DB-Wax(30 m×0.53 mm×1.00μm).The carrier gas was nitrogen and FID as detector.The injector temperature was 200℃,and the detector temperature was 250℃.The initial column temperature was kept at 34℃ for 4 rain with an increase rate of 10℃·min~(-1) to 60℃,then 50℃ ·min~(-1) to 160℃ (sustained for 5 rain).The quantification of residual solvents was calculated by external standard method.Results:Under the above condition,there was good linear relationship in the concentration range measured, the recoveries and RSDs ranged from 91.0% to 106.2% and 2.2% to 5.2%,respectively.Conclusion:The meth- od is simple accurate and reproducible.