Effect of different disinfection methods on surface free energy and Shore hardness of carbon ion-implanted silicone rubber

Xin Zhou,Xing Chen,Xiaohua Shi,Shaoliang Wang,Zeyuan Lei,Dongli Fan,Yiming Zhang
DOI: https://doi.org/10.16016/j.1000-5404.201510156
2016-01-01
Abstract:Objective To study the changes of surface contact angle,surface free energy and Shore hardness of carbon ion-implanted silicone rubber disinfected by different methods.Methods Carbon ionimplanted silicone rubber was treated with 70% alcohol,2% alkaline glutaraldehyde,0.5% iodine volts,5.25% sodium hypochlorite,3% hydrogen peroxide respectively,and high temperature of 134℃ under high pressure for 2 h,and then the surface contact angle and Shore hardness were tested with a contact angle instrument and a Shore durometer (type A).Surface free energy,polar component and nonpolar component were calculated with Owen-Wendt methods.Results The surface quality of carbon ion-implanted silicone rubber was changed after disinfection with 3% hydrogen peroxide and 5.25% sodium hypochlorite,and 5.25% sodium hypochlorite even made the surface in highly hydrophilic state.There was no effect on the surface quality after disinfection with 70% alcohol,2% alkaline glutaraldehyde,0.5% iodine volts and high temperature of 134 ℃ under high pressure.The Shore hardness was not affected by all the disinfection methods.Conclusion 70% alcohol and high temperature of 134 ℃ under high pressure have the minimal effects on the surface free energy,and based on operation convenience,70% alcohol is considered as the optimal disinfection method for carbon ion-implanted silicone rubber.
What problem does this paper attempt to address?