Determination of Phenobarbital,Phenytoin and Carbamazepine in Serum by RP-HPLC

汤文璐,王永铭,伍章保,屈建
DOI: https://doi.org/10.3969/j.issn.1672-8467.2003.01.022
2003-01-01
Abstract:Purpose To develop a method for simultaneously determining the concentrations of phenobarbital(PB),phenytoin(PT),carbamazepine(CBZ) in serum by RP?HPLC. Methods The serum samples,added barbital as the internal standard,were extracted two times with aether.The organic phase was evaporated at 45?℃.The residue was dissolved by methanol.YWG C 18(4.6 mm×300 mm,10 μm) column was used;mobile phase:MeOH?H 2O(55∶45),flow rate 0.5 mL/min.The detective UV wavelength was 230 nm. Results The parameters of PB,PT and CBZ were as follows respectively:t R 11.77,17.53,22.29 min;the lowest detection concentration 0.25,0.15,0.05 μg/mL;the linear relation was in the range of 0.5-80(r=0.999 7),0.25-40(r= 0.999 6),0.25-20(r=0.999 1) μg/mL.The average recoveries were 101.44%,100.07%,102.09%.The intra-day precision were 2.77%,4.26%,1.54%.The inter-day precision were 5.95%,3.37%,5.02%. Conclusions The method was found to be accurate,convenient and effective.It is suitable for therapeutic drug monitoring of antiepileptic drugs and clinical pharmacokinetic study.