Comparison of bonding strength in two different designs

Xiao-Xi ZHANG,Hong-shui ZHU
DOI: https://doi.org/10.3969/j.issn.1000-2294.2005.06.037
2005-01-01
Abstract:Objective To compare the bonding strength of two ways about making model.Methods Tweenty-four extracted teeth block were bonded with Ni-Cr alloy and 24 resin block were bonded with Ni-Cr alloy by two kinds of adhesive material. They were Gluma Comfort bond and Single bond.These bonding complexes were stored in normal saline for 72 hours.Then shear bond strengths and tensile strengths were measured respectively.Results There was significant difference in shear bond strength and tensile strengths between two kinds model as 2 X 2 factorial design and analysis of variance SPSS 10.0. There was no significant difference in shear bond strengths and tensile strengths between two kinds adhesive.Conclusion The model of dental-resin-mental was significant less in shear bond strength and tensile strengths than that of resin-mental,but is more similar to clinical.
What problem does this paper attempt to address?