Finite element stress analysis of titanium post and fiber post after repairing maxillary incisor reidual root

崔蜜,董少杰,兰亭,张辉,逯宜,牛林
DOI: https://doi.org/10.3969/j.issn.1000-7377.2017.03.001
2017-01-01
Abstract:Objective:Models of maxillary central incisor residual root restored with titanium post-core crown and fiber post-core crown were built to analyze the stress distribution on the posts by finite element method .Meth-ods :The sample was scanned by Inveon Micro-CT technology from incised margin to root apical at a 21μm interval to obtain transverse sectional images .The three-dimensional finite element model was created by rebuilding the mor-phology of maxillary central incisor with inveon research workplace ,combined Mimics ,geom-agic and catia soft-ware .The model was meshed and loaded to analyze the stress distribution on the post by finite element method .Re-sults :The maximum stress ,shearing stress and equivalent stress on the fiber post were 90% less than that on the titanium post in the experiment .All parts of the titanium post had higher stress than the fiber post .Furthermore , the stress concentration mainly occurred on the labial surface of the middle 1/3 of root ,which reached 33 .59 MPa , while the stress on the area of fiber post was merely 0 .6 MPa .Conclusion :The finite element analysis indicated that the fiber post-core crown is better than titanium post-core crown to avoid stress-concentration and post or root frac-ture on the natural residual root of central incisors with dentin ferrule .
What problem does this paper attempt to address?