The application of FloTrac/Vigileo system in gynecological laparoscopic surgery perioperative hemodynamic monitoring

张会娟,张勇,熊虹飞,刘鸿涛,田妍静,雷茜,何丽丽
DOI: https://doi.org/10.3969/j.issn.1000-7377.2015.03.017
2015-01-01
Abstract:Objective :Using FloTrac/Vigileo system to detect the changing of gynecologic laparoscopic surgery perioperative cardiac output (CO) .Methods :120 patients were randomly divided into three groups .40 ca‐ses of each group .The pneumoperitoneum pressure of group A was 10mmHg ;The pneumoperitoneum pressure of group B was 12mmHg ;The pneumoperitoneum pressure of group C was 15mmHg .The patients were recorded be‐fore induction of anesthesia after resting 3min (T0),and 5min after trachea intubation (T1),5min after pneumoper‐itoneum (T2),15min after pneumoperitoneum (T3),30min after pneumoperitoneum (T4),1 minutes after the end of pneumoperitoneum(T5),and 5 min after pneumoperitoneum (T6)and 5min after extubation (T7)The CO ,HR and MAP ,of each time point was observed and recorded .Results :The HR and MAP of the three groups after pneu‐moperitoneum was increased significantly and there was no significant difference before and after pneumoperitoneum in CO .Conclusion:For short than 60 minutes gynecologic laparoscopic surgery ,using 10 ~ 15mmHg the cardiac output is no apparent effect .