Experimental Research on the Ground Thermodynamic Vent System

Zhan LIU,Shaohua ZHANG,Xiaoyu ZHANG,Xin LIU,Yanzhong LI
DOI: https://doi.org/10.7652/xjtuxb201707002
2017-01-01
Abstract:To conduct in-depth study on the performance of tank pressure control and the ability of heat leakage removing,an experimental rig was built to research the performance of thermodynamic vent system (TVS) with the simulant fluid of R123.The experimental research under three operation modes of tank pressurization,mixing injection depressurization and throttling refrigeration were conducted at the heat load of 800 W and the initial liquid height of 0.595 m.The tank pressure variation and fluid temperature change were analyzed duringdifferent operation modes.The results showed that,subjected to the external heat leak,the tank pressure rising rate was about 60.583 kPa/h during the tank pressurization phase;while in the mixing injection phase,increasing the circulation volume flow was beneficial to the reduction of vapor temperature.With the circulation volume flow of 150 L/h and the throttling rate of 11.73%~13.33%,the total venting gas was 20.536 kg for 8 throttling operation cycles.The maximum refrigeration capacity of one throttling operation cycle was 1 362 W.Compared with the direct venting gas approach,TVS has saved 41% exhaust loss for 2 hours' operation.The valuable conclusion could provide a technical reference for a further experiment on the cryogenic fluid thermodynamic vent system.
What problem does this paper attempt to address?