Three Phase Passive AC-DC Converter with High Input Power Factor
Yang Xijun,Liu Xiang,Jiang Jianguo
2005-01-01
Abstract:When the three phase uncontrolled rectifier is employed as the front stage of power converter, the input current waveform factor is low,which leads to lower input power factor and power supply utilization. Therefore, it is necessary to introduce power factor increasing techniques. Passive power factor correction is one of the techniques, which is very useful in some applications. In the paper, several three phase passive AC-DC converters with high input power factor are depicted, such as LC filter, resonant reactor, phase-shifting reactor, phase-shifting transformer, interphase reactor and interphase transformer. After simple analysis, the simulated results by MATLAB/SIMULINK. are provided.