Abstract:The bond-slip experiments were conducted to reveal the influence of the composite connectors on the mechanical properties of the steel tube and the surrounding concrete.The composite connectors consist of annular plate,stiffening plate and welding nails between the steel pipe and the surrounding concrete. The bond-slip curves and the cracks distribution were obtained on the basis of the experiments.Then,the numerical simulation analysis was carried out and compared with the results of the standard calculation. Results show that the characteristic slip of the steel tube with the composite connectors is more than 6 mm,which meets the standard Eurocode-4 requirements for ductile connectors.The combination of annular plate and stiffening plate takes advantage of the compressive strength of the concrete sufficiently.The welding nails has improved the elastic anti-slip stiffness of the interface effectively.Increasing the ratio of welding nails can enhance the plastic anti-slip stiffness and ultimate strength of the interface,and welding nails of high ratio don't change the character of welding nails as the ductile connection.The actual ultimate load value of single welding nail is nearly consistent with the calculate value of the codes.
What problem does this paper attempt to address?