Abstract:Glass-fiber-reinforced polymer(GFRP)-foam composite sandwich plate wall panel,which were manufactured through the vacuum infusion molding process,is regarded as the research object. According to ASTM D7136M—2005, the impact tests and the compression tests after impact were carried out to evaluate the performance of the composites and the GFRP-foam sandwich wall panels at elevated temperature. Impact load-time histories and load-displacement curves at different locations of the wall panels were measured. The test results shows that with the temperature increase, impact contact force decreases.The compression strength after impact was used to evaluate the impact toughness of GFRP composite sandwich wall panels. The test results show that with the temperature increases, the impact toughness decreases. Regardless of the temperature, the impact point of the web can help improve its impact contact force and impact toughness.
What problem does this paper attempt to address?