Experimental Investigation on Instability of Linear Compressor in Refrigerator

邹慧明,李灿,唐明生,田长青
DOI: https://doi.org/10.3969/j.issn.0253-4339.2017.03.050
2017-01-01
Abstract:The instability of a linear compressor is studied by an experiment on a developed linear compressor in a refrigerator. The ex-perimental results show that there are three types of unstable phenomena:the start-up process, external disturbance process, and solenoid valve adjustment process. During the start-up process, an unstable status is caused by the adjustment of the supply power and changes in the refrigerant suction/discharge pressure. This finally settles down as the supply power and suction/discharge pressure are unchanged. Some external disturbance of the refrigeration system causes an unstable oscillation with a fluctuation of about 0. 3 mm of the piston dis-placement. Accordingly, the current and the input power fluctuate at about 10% of their average values. This oscillation gradually be-comes stable as there is no more disturbances. The solenoid valve adjustment process has a great influence on the stability of a linear com-pressor. In this experiment, the maximal fluctuation amplitude of the displacement is about 2. 2 mm, and the piston is apt to strike the cylinder. Therefore, the design optimization for a linear compressor structure, and a control strategy based on the change characteristics of the working conditions, is necessary to ensure operational reliability and high efficiency.
What problem does this paper attempt to address?