The difference in the thermal response under non-equilibrium aerodynamic heat

Mingxing YU,Shuxin BAI,Xiaoliang XU,Zhanwei CAO
DOI: https://doi.org/10.11951/j.issn.1005-0299.20170255
IF: 1.8
2017-01-01
Materials Science and Technology
Abstract:In this paper, considering the difference of the thermal responses between C/C and ultra high temperature ceremics ( UHTC) in wind tunnel ablation tests, three conditions based on two heating facilities have been designed, and the important factors influencing the thermal responses have also been analyzed from the viewpoint of materials surface catalytic and non-equilibrium flow field aerodynamic heat. The results indicated that, the difference in the stagnation temperature of C/C ends using the different testing facilities is mainly caused by the debugging deviation and temperature measurement deviation under testing conditions, whereas the difference in the stagnation temperature of UHTC ends is mainly attributed to the different in the non-equilibrium degree and the actual surface heat flow. When selecting the testing facilities, non-equilibrium degree of the flow field needs not to be considered due to the fact that C/C surface catalytic properties are close to fully catalytic one, whereas, for UHTC, the non-equilibrium flow field should be considered to fully assess the validity of the testings. The results obtained in this work can shed more insights on the assessment and evaluation of the thermal protection performance for the C/C, and UHTC composites.
What problem does this paper attempt to address?