Improvement on Determination of Sulfide in Waste Water by Iodometry

Wen-chao ZENG,Yong SHAO,Li-chao AN,Guang-dong LIU
DOI: https://doi.org/10.11973/lhjy-hx201701014
2017-01-01
Abstract:Optimization for the conditions described in the standard method of iodometric determination of sulfides in waste water (HJ/T 60-2000) was made scrutinously,and the following modifications were given:① temperature of the water bath chosen:65 ℃;(②) flow-rate and time of the 3 N2-blowings:80 mL · min-1 and 20 min for the 1st blowing,300 mL · min-1 and 10 min for the 2nd blowing and 400 mL · min-1 and 6 min for the 3rd blowing;(③) 1 mol · L-1 zinc acetate solution was selected as absorbent,and 3 mL of the solution were used to absorb H2S liberated from the sample solution containing ≤1.5 mg · L 1 of sulfides;④ the modified method was proved to be valid for samples containing sulfides in the range of 0.4-3 mg · L-1 and the portion of sample used for the determination should contain sulfides ≤1.5 mg · L-1.On the base of waste water samples as matrixes,test for recovery of the proposed method was made by standard addition method,results of recovery found were in the range from 94.4% to 94.9%,with values of RSDs (n=6) ranged from 2.3% to 3.4%.
What problem does this paper attempt to address?