Amended Deviations of Iodometric Method for Determination the Concentration of H_2S in Crude Oil

XU Tian-Feng,SUN Hai-Jiao,LIU Qiang,LIU Ji-Ning,ZHANG Zhao
2011-01-01
Abstract:The classic iodometric technique for determination the concentration of H2S in crude oil was simple but possessed lots of deviations,and there was no better way that could take it place till now.Through revising the technique of "determination of hydrogen sulfide content—iodometric titration method",an empirical formula between the theoretical value(y) and the measured value(x) of H2S concentration in crude oil was obtained,y=-0.2624x2+1.8824x+0.279,which could amend the measurement error when H2S concentration was in the range of 0≤x≤3 mg/g.While x<0.8396 mg/g,a simplified linear formula y=1.8824x+0.279 derived from the empirical formula was used,which could make sure that the relative error between y and x was no more than 10%.