Study on comparison the determination of residue of sulfur dioxide in traditional Chinese medicine by ion chromatography and titration

Pi Wen-xi
Abstract:Objective To establish a method for the determination of residue of sulfur dioxide in traditional Chinese medicine. Methods The samples were extracted by wet distillation under acidic conditions,with 3% hydrogen peroxide as absorption liquid, and then determined by ion exchange- ion chromatography conductivity detection. The determination was performed on IonPac@ AS11- HC( 250 mm × 4 mm) ion exchange column with mobile phase consisted of 20 mmol / L KOH at a flow rate of 1 ml / min, the column temperature was set at 30 ℃,the detection cell temperature was set at 35 ℃. Results The linear range of sulphate was 1 ~ 200 μg / ml( r = 0. 999) with an average recovery of 80. 80% ~ 103. 07%( RSD = 1. 73% ~ 7. 62%). Conclusion The method is sensitive,specific,automatic and simple.
Chemistry,Medicine
What problem does this paper attempt to address?