Thermal protection structure design and heat transfer analysis of linear actuator in cryogenic wind tunnel

Xudong Wang,Shuping Chen,Hongwei Mao,Dan Liu,Shuting Yao
DOI: https://doi.org/10.3969/j.issn.1000-6516.2017.06.012
IF: 2.134
2017-01-01
Cryogenics
Abstract:To solve the thermal protection problem of linear actuator in cryogenic wind tunnel,a thermal protection structure which can make it work normally under both high temperature condition (323 K) and cryogenic condition(110 K) was designed.The strength and rigidity of the thermal protection structure were checked.The temperature change of the linear actuator caused by the factors such as heat dissipation of motor,flow rate of cooling gas and heating power of heating plate were studied through numerical simulation method.It is found that when the pressure in the cryogenic wind tunnel reaches the extreme value of 0.35 Mpa,the maximum deformation and stress of the cylindrical thermal protection structure,made of stainless steel S30408 with thickness of 5 mm,is 0.397 mm and 160.62 Mpa respectively.When the flow rate of cooling gas≥0.005 kg/s,the maximum temperature of motor under high temperature and cryogenic condition are not greater than 418 K,which is the allowable operating temperature of motor.When heating power reaches 500 W,the checked section temperatures of the cylinder rod end are all higher than 263 K.Under the high temperature and the cryogenic condition with heating power 500 W,the operating temperature of cylinder and cylinder rod can be maintained at 263-313 K when the flow rate of cooling gas is 0.005 5 kg/s.Under the high temperature condition,the maximum temperature rise and temperature difference are 3.62,2.81 K respectively,the maximum temperature drop and temperature difference of the cryogenic condition are 4.94,6.82 K respectively,which meet the requirements of temperature stability and uniformity.
What problem does this paper attempt to address?