Design and performance analysis of screw lift thermal protection structure in the cryogenic wind tunnel

Dan Liu,Shuping Chen,Hongwei Mao,Xudong Wang,Shufeng Jin,Shuting Yao
DOI: https://doi.org/10.16711/j.1001-7100.2018.01.004
2018-01-01
Abstract:A three-section thermal protection structure with the stainless steel pressure protection shell and built-in polyurethane insulation layer was designed according to the structural characteristics of screw lift and the engineering thermal protection requirements of devices in the cryogenic wind tunnel.The numerical model of thermal protection structure was established by using finite element software,and its stress,deformation and temperature distribution were obtained on the basis of the structural and thermal analysis under the low temperature and normal temperature conditions.It is found that when withstanding the maximum pressure difference of 0.35MPa,the thermal protection structure has the maximum stress,and the strength of thermal protection structure meets the requirements under normal working loads through strength check.The load factor of the thermal protection structure is 74.5 (> 3) and its first order buckling load is 26.1MPa(> 0.35MPa),thus the stability of thermal protection structure meets the requirements.Under the low temperature and normal temperature conditions,the temperature of screw lift structure is in the safe range of 263K-313K when the mass flow rate of nitrogen gas is 0.01 kg/s and 0.02kg/s respectively,inside the thermal protection structure with the polyurethane thermal insulation thickness of 40mm.
What problem does this paper attempt to address?