Research on temperature controlling for GMA based on direct liquid cooling

LI Jia-qi,WU Yi-jie,ZHANG Lei,Wang Bin
DOI: https://doi.org/10.3969/j.issn.1001-4551.2011.07.003
2011-01-01
Abstract:In order to provide a stable working temperature for giant magnetostrictive actuator(GMA),thereby ensuring its high-precise-output,aiming at improving the thermal efficiency of traditional temperature controlling method,a novel high thermal efficiency temperature controlling method as well as a new chuck-style thermal structure,were proposed for flexure type GMA on the basis of direct liquid cooling principle.Simulation results show that the novel direct liquid cooling method with multi-layer oil tunnels could provide a temperature disturbance range of ±0.02 ℃ for giant magnetostrictive material(GMM) compared with previous results of ±0.4 ℃~±0.5 ℃ by the traditional method,and the novel temperature controlling method and thermal structure will shed light on further application research and development utilizing GMM.