Research on ‘Transformer-Inductance’ Impedance Matching Model for Ultrasonic Transducer

HAN Xu,ZHANG Kang-ning,ZHENG Hai-xiang,MA Qing-yu
DOI: https://doi.org/10.16300/j.cnki.1000-3630.2015.04.017
2015-01-01
Abstract:Based on the analyses of impedance characteristics and matching circuit of ultrasound transducer, it is found that with the traditional inductance capacitance matching circuit, a wide range of reactance variation around the reso-nant frequency appears and causes the circuit stability and regulatory accuracy reduced. Therefore, a ‘transfor-mer-inductance’ matching model is proposed in this paper. The reactance and resistance can be regulated by the ad-justable inductance and transformer to improve the precision and stability of the matching circuit for ultrasonic trans-ducer, and the ideal matching condition and parameter are provided. In experiments, with the controllable transformer and inductance, a matching circuit is developed for an ultrasonic horn transducer with the center frequency of 20.8 kHz. It is proved that the matching circuit has a narrow impedance variation range with high reactance regulatory ac-curacy when the frequency is close to the resonance, which provides application potential in automatic impedance matching of ultrasonic transducer.
What problem does this paper attempt to address?