RESEARCH ON DETERMINATION OF TRACE ACID IN JET FUEL BY THERMOMETRIC CATALYTIC TITRATION

Yongliang Xin,Jianqiang Hu,Shizhao Yang,Li Guo,Binghao Chen
DOI: https://doi.org/10.3969/j.issn.1005-2399.2017.12.021
2017-01-01
Abstract:Using paraformaldehyde as a catalytic indicator,the trace acid in the jet fuel sample was determined in an inclosed temperature titration device under optimal conditions.The accuracy of the method was verified by comparing the results with that of standard acid method.The results showed that when the oil sample is 10,15,20,25,30 g and the titration concentration 0.01 mol/L and the titration rate 1.0 mL/min with moderate stirring,the titration results have good reproducibility and accuracy.The linear coefficient R2 of the fitting curve is 0.995.Using benzoic acid as a standard acid with concentration of 0.010 5 mgKOH/g to verify the accuracy of the new method,the measured results are 0.011 5 mgKOH/g,basically consistent with the actual acid value,indicating that the thermometric catalytic titration can be used as a new method of measuring acid value for jet fuels.It can accurately determine the acid value of jet fuel as low as 0.015 mgKOH/g or even lower at optimized test conditions.
What problem does this paper attempt to address?