Aspen Plus Predict Water Dew Point and Ph Value of the Overhead Condensing System of Crude Atmospheric Distillation Unit

WANG Haibo,LI Yun,OUYANG Wenbin,CHENG Guangxu,ZHANG Yaoheng,LI Xinyun
DOI: https://doi.org/10.3969/j.issn.1001-8719.2018.03.025
2017-01-01
Abstract:Based on Aspen Plus simulation,a method for forecasting water dew point in tower overhead system was developed.The water dew point is 95.8℃.The operating pressure of tower overhead system increased by 10 kPa resulting in increasing of the water dew point about 2℃.The water injection rate is 5000 kg/h,to ensure that the water injection point has enough condensing water to avoid corrosion.The temperature of the serious corrosion area in tower overhead system is 95.8-102℃,and the pH values of condensed water ranges between 2 and 3.Aspen Plus simulation works well to predict water dew point and the pH value of initial condensed water in tower overhead system,which provide a scientific basis for corrosion prediction and equipment controlling.