Experimental Study on Water Quality Stabilization Using the Low Frequency Electromagnetic Treatment of Reclaimed Water

CHI Jin-bao,ZHAO Min,CANG Da-qiang,ZHANG Xue-feng,CHANG Rui-qing
DOI: https://doi.org/10.3321/j.issn:0449-749x.2009.08.023
2009-01-01
Abstract:According to scaling and corrosion problems during operation process of circulating cooling water,a water quality stabilization experiment was conducted on treatment reclaimed water with low frequency gradient electromagnetic field.The effects of electromagnetic treatment on scale and corrosion inhibition were mainly investigated.The experimental results show that scaling and corrosion problems on non-heat-transfer surface could be controlled significantly.The fouling deposition rate and the corrosion rate were reduced to 35.02 mg/(cm2·month) and 0.136 mm/a under dynamic simulation test from 56.85 mg/(cm2·month) and 0.834 mm/a under static test respectively,and were both keeping decreasing.But scaling problem on heat-transfer surface was serious,the fouling deposition rate was 184.59 mg/(cm2·month),but the corrosion rate could be controlled significantly,which was 0.158 mm/a.Through XRD(X-Ray Diffraction) analysis,it was found that the massive Mg2+ in reclaimed water could inhibit the scale inhibition of electromagnetic treatment,while promoting the formation of compact MgFe2O4 protective film on iron surface under electromagnetic treatment,which is against corrosion.