Abstract:A new electromagnetic water treatment device for anti-scaling treatment was prepared by combined DC pulse with frequency conversion technology.Using a test sheet,the anti-scaling efficiency of magnetic treatment was measured under different magnetic treatment conditions.The experimental results indicated that the pulsed magnetic field had obviously anti-scaling effect.The best anti-scaling efficiency was over 90%.Including intensity and retention time,some magnetic treatment parameters have very important effect on the anti-scaling performance of magnetic field,such as magnetic field direction,magnetic strength,materials pipe wetted and flow velocity.The stronger anti-scaling effects were obtained by the application of vertical heterogeneous magnetic field direction.The anti-scaling efficiency of magnetic treatment was increased with the increasing of field intensity,treatment time and magnetic range.The SEM analysis showed that the magnetic field affected the crystal process of scale and changed its form and structure.